Precision Voltage Output Accelerometers 100 Series

Economic Version

100 Series Economic Version

  • Build-in circuitry made in USA
  • Annular shear design with 2 sensitivities: 5mV/ ms-2 and 10 mV/ ms-2
  • Top output connector with 2 metric threads, M5 and M6
  • Choices of isolated and non-isolated mounting base
  • Offer side output connector as customer special

Specifications

Model

Unit

13108

13110

13111

13112

14108

14110

14111

14112

Sensitivity

mV/ms-2

5

5

5

5

10

10

10

10

Frequency Range

±10%

Hz

0. 5~10000

0. 5~9000

0. 5~10000

0. 5~9000

0.5~10000

0.5~8000

0.5~8000

0.5~9000

Resolution

m/s2

0.002

0.002

0.002

0.002

0.001

0.001

0.001

0.001

  Mounting Resonance

KHz

30

28

30

28

27

24

27

26

Measurement Range

m/s2

1000

1000

1000

1000

500

500

500

500

Operating Temperature

-50~125

Base Insulation Resistance

Ω

0

>1×108

0

>1×108

0

>1×108

0

>1×108

Weight

gram

23

23

23

23

25

25

25

25

Dimension

HexxHxC

mm

17x21x27