Sputum Collection Negative Pressure Booth
By SP Sonic
Infection of tuberculosis germs and effect of Sputum Collection Negative Pressure Booth
Infection of tuberculosis germs occurs by sucking droplet nuclei of tuberculosis germs coughed
out by a tubercular patient and flying all around. Therefore, the elimination of infection path is
essential for the prevention against infection of tuberculosis.
The sputum collection negative pressure booth prevents dispersal of droplet nuclei coughed
out by a patient by keeping the pressure inside the booth negative. Furthermore, the HEPA filter
and UVC lamp installed in the booth eliminates the droplet nuclei floating inside the booth.
















 

HEPA Filter UV-C 




SP SONIC CO.,LTD.
53/8 Soi Ramindra 40, Nuanchan, Buengkum, Bangkok 10230, Thailand.
Tel. 02-007-0604 Fax. 02-944-6451 Email: info@spsonic.co.th
Features
SP SONIC CO.,LTD.
53/8 Soi Ramindra 40, Nuanchan, Buengkum, Bangkok 10230, Thailand.
Tel. 02-007-0604 Fax. 02-944-6451 Email: info@spsonic.co.th
Outside dimensions
1100 (W) x 1500 (L) x 2300 (H)
Inside dimensions
950 (W) x 950 (L) x 2100 (H)
Weight
About 250 kg
Airflow rate
>200 m
3
/hr.
Main filter
HEPA filter (99.97% of 0.3
-µm particles) & Activated carbon HEPA filter
Blower
0.18 m
3
/min./watt (at hi switch)
19Watt (50/60 Hz), 1,125 RPM.
Air supply opening
Perforated punching metal (with pre
-filter)
Air inlet
Plastic
grille
Exhaust opening
Plastic grille
Lighting
LED 10 Watt
Casing
Galvanized steel sheet with powder coat
UV
-C lamp in room
25 Watt
UV
-C lamp in filter
chamber
25 Watt
Operation panel
Main Power supply ON/OFF switch, Switch for LED lighting , Operating
condition indicator of two UV
-C lamp, Blower Hi/Low switch
Alarm indicator
Differential pressure alarm Hi/Low
Pressure
Digital Differential pressure LED display (indicating differential pressure of
HEPA filter)
Power consumption
100W (excluding capacitance of inside plug outlet)
Power supply
Single
-phase 220 VAC, 50/60 Hz
High performance HEPA filter.
Negative pressure controller.
Easy relocation.
UV-C lamp in room & HEPA filter chamber.
Roof mounted ventilation.
Digital differential pressure display &
microcontroller operating.
Differential pressure alarm.
1.LED Operating
2.Digital Differential
pressure LED display
3.Pressure Alarm
4.Blower hi/low switch
5.LED lighting in room
6.UV lamp in chamber
7.UV LED display
8.Power supply on/off switch
9.UV lamp in room
1500 mm.
1100 mm.
2300 mm.
1
3
4 5 6 7
8 9
2
Galvanized steel sheet
with powder coat
Plastic grille
Perforated punching
metal (with pre-filter)
UV-C lamp in room 25 Watt
Stainless handle
แผ่นกรองอากาศ HEPA Filter
Sputum Collection Negative Pressure Booth
By SP Sonic
Maintenance
การบ ารุงรกษา
1. การบ าร
งรักษาประจ าวัน
Isolate Room





10-15 Pascal



2. การบ าร
งรักษาประจ าเดอน
1 

1 
1 
3. การบ าร
งรักษาประจ าป





2.5 in.wg 


3

Pre Filter
1

HEPA Filter
3-5

4,000
3 

Sputum Collection Negative Pressure Booth
By SP Sonic
SP SONIC CO.,LTD.
53/8 Soi Ramindra 40, Nuanchan, Buengkum, Bangkok 10230, Thailand.
Tel. 02-007-0604 Fax. 02-944-6451 Email: info@spsonic.co.th